Weight Transmitter E LINK 3000 Ethernet

E LINK 3000 Ethernet

The weight transmitter E LINK 3000 Ethernet can be integrated into any industrial regulation and supervision system. This weight instrument has 5 different electronic configurations and 5 different enclosures for every installation requirement. The weight transmitter E LINK 3000 Ethernet can be configured from a PC, by using a dedicated software or directly from the Master via the communication protocol. Its main functions are: field and remote fault diagnostics, faulty cell emulation function with exclusion from the weighing system and automatic recalibration of the new load cell. The weight transmitter E LINK 3000 Ethernet owns two serial ports: COM1: RS232 for parameter configuration from pc and Ethernet. E LINK 3000 Ethernet has a RJ-45 connector for electrical connection to load cells. PWS: 31/2015

Further Information

Technical Specifications in PDF

Product code: -_-

Technical Specifications

Input sensitivity: 0.003 µV/count
Full scale non-Linearity: < 0.01%
Gain drift: < 0.003% FS/°C
A/D Converter: 24 bits
Internal Resolution: > 16.000.000 points
Temperature range: -10 ÷ +50°C
Storage temperature: -20 ÷ +70 °C
Excitation voltage: 5 Vdc
Serial port: COM1: RS232 (for configuration parameteRS from a PC); COM2: Ethernet
Power supply: 12 ÷ 24 Vcc
Regulatory compliance: EN 61000-6-3, EN 61000-6-2
Dimensions: 130x100x60 mm (WxHxD) card of support for DIN rail
Fieldbus: Ethernet
Number of readings per second: 0.1 ÷ 72 based on the number of cells and on the digital filter value
Input signal cells: -5 mV/V ÷ +5 mV/V

Certifications

  • EAC