The HTU product is a tensiometric system suitable for working in extreme conditions where very high temperatures are regularly reached. This weighing system has been tested. Furthermore, the calibration of HTU is set up directly at the workplace to guarantee minimum start-up time. PWS: 20/2012
Technical Specifications in PDF
Rated load RL: 9, 27, 45, 89 kN |
Combined error: 0.1 % RO |
Repeatability: 0.02 % RO |
Creep (20 minutes): 0.05 % RO |
Safe overload: 150 % RL |
Ultimate overload: 300 % RL |
Safe sideload: 100 % RL |
Ultimate sideload: 300 % RL |
Degree of protection: IEC IP67 |
Temperature range: -18 ÷ +149°C |
Storage temperature: -18 ÷ +121 °C |
Temperature effect on zero balance: 0.0044 % RO/°C |
Temperature effect on output: 0.0089 % RO/°C |
Rated output RO: 2.0 mV/V (X & Y bridges) |
Zero balance: 1.0 % RO |
Input resistance: 185 ±10.0 Ohm |
Output resistance: 500 ±5.0 Ohm |
Recommended input: 10 ÷ 15 Vdc/ac |
Weight: 8.2 kg |
HTU Cell: 17-4PH stainless steel |