Weighing Module PERMOUNTING

PERMOUNTING

The PERMOUNTING weighing module has a pin load cell (double shear beam operation) made of fully welded steel and a built-in mounting component. The PERMOUNTING weighing module is suitable for tension measurements and all weighing systems. PERMOUNTING offers maximum resistance to impacts and overloads and is insensitive to side loads. The PERMOUNTING cell is supplied with a 5 meter long cable with 6 conductors and a length of 5 mt. The load cell and the mounting component of the PERMOUNTING product cannot be sold separately, the weighing module must be purchased in full (see image). PWS: 07/2018

Further Information

Technical Specifications in PDF

Product code: -_-

Download  

Technical Specifications

Rated Load (RL): 5, 10, 20, 40, 60, 80, 100 t
Combined error: < ±0.1 % RO
Repeatability: < ±0.02 % RO
Creep (20 minutes): ±0.03 % RO
Safe overload: 150 % RL
Ultimate overload: 300 % RL
Material: Stainless steel
Degree of protection: IP68
Deflection: 0.4 mm
Compensated Temperature: -10 ÷ +50 °C
Temperature range: -20 ÷ +70 °C
Temperature effect on zero balance: < ±0.005 % RO/°C
Temperature effect on output: < ±0.005 % on output/°C
Rated output RO: 1 mV/V ±0.1 %
Zero balance: < ±2 % RO
Insulation resistance: > 5000 MOhm
Input resistance: 700 ±20 Ohm
Output resistance: 700 ±10 Ohm
Recommended input: 5 ÷ 15 Vdc/ac

Certifications

  • EAC

Related products