Tedea load cell 240

240

The Model 240 is speciically designed to be used where the fast acquisition of a stable load signal is paramount. The Model 240’s unique fluid damping system allows the load cell to be used in applications that previously required the use of LVDT’s or similar measuring devices. The Model 240 brings load cell adaptability into check weighing and grading applications. Approved to OIML R60 and NTEP standards, sealed to IP66 level and available in coated steel or stainless steel, the Model 240 is suitable for most wash-down applications. The two additional sense wires feed back the voltage reaching the load cell. Complete compensation of changes in lead resistance due to temperature change and/or cable extension, is achieved by feeding this voltage into the appropriate electronics. PWS: 09/2019

Further Information

Technical Specifications in PDF

Product code: -_-

Download  

Technical Specifications

Rated Load (RL): 2, 3, 5, 7, 10, 15, 20, 30, 50 kg
Ultimate overload: 300 % RL
Material: Painted mild steel
Degree of protection: IP66
Accuracy class: C3
Compensated Temperature: -10 ÷ +40°C
Temperature range: -30 ÷ +70°C
Temperature effect on zero balance: ±0.0026 % (NTEP); NA (Non Approved); ±0.0026 % (C3) RO/°C
Temperature effect on output: ±0.0010 % (NTEP); NA (Non Approved); ±0.0010 % (C3) RO/°C
Rated output RO: 2 mV/V
Zero balance: ±0.10 mV/V
Insulation resistance: > 1000 MOhm
Input impedance: 415±15 Ohm
Maximum input voltage: 15 Vdc or Vac rms
Nominal input voltage: 10 Vdc or Vac rms
Cable Lenght: To suit m
Output impedance: 350±3 Ohm

Certifications

  • OIML
  • NTEP

Related products