The off center load cell 1260, made of aluminum, is robust and precise and ideal for large-scale single-cell platforms. This load cell maintains precision in any position the object is loaded and this solves the problems that usually occur in weighing systems if the object does not rest exactly on the center of the cell. The off center load cell 1260 has a 6 meter long shielded cable with 6 wires. PWS: 39/2014
Technical Specifications in PDF
Rated load (RL): 50, 75, 100, 150, 250, 300, 500, 635 Kg |
Combined error: ±0.02 % RO |
Repeatability: ±0.015 % RO |
Creep (30 minutes): ±0.0170 % of applied load |
Safe overload: 150 % RL |
Ultimate overload: 300 % RL |
Degree of protection: IP66 |
Compensated Temperature: -10 ÷ + 40 °C |
Temperature range: -20°C ÷ +70°C |
Temperature effect on zero balance: ±0.0023 % RO/°C |
Temperature effect on output: ±0.0010 % of applied load/°C |
Rated output RO: 2.0 mV/V |
Zero balance: ±0.2 mV/V |
Insulation resistance: >2000 MOhm |
Input resistance: 415 ±15 Ohm |
Cable Lenght: 3m |
Maximum platform size (mm): 600 x 600 |
Maximum excitation: 15 Vdc/ac RMS |
Excitation recommended: 10 Vdc/ac RMS |
Output impedance: 350 ±3 Ohm |