Shear beam load cells PTA

PTA

The PTA shear beam load cell, built in nickel-plated steel, has excellent precision, linearity and creep characteristics and has been designed for weighing tanks, hoppers, belts, platforms, single-cell systems, suspended loads and automatic packaging machines. The PTA cell is resistant to lateral loads exceeding 50% of the Rated Capacity and is supplied with a 4-conductor shielded cable 4 meters long (0.5 - 2 t) or 6 meters (3 - 5 t). The PTA bidirectional load cell is suitable for tension and compression industrial applications. PWS: 11/2017

Further Information

Technical Specifications in PDF

Watch our tutorial

Product code: -_-

Download  

Technical Specifications

Rated Load (RL): 0.1, 0.25, 0.5, 1, 1.5, 2, 2.5, 3, 5 t
Combined error: ±0.023 % RO
Repeatability: ±0.01 % RO
Creep (30 minutes): ±0.02 % RO
Safe overload: 150 % RL
Ultimate overload: 300 % RL
Clamping force without any load: M12= 75Nm; M18= 500Nm
Material: Stainless steel
Degree of protection: IP67
Accuracy class: 3000 OIML
Deflection: 0.2 ÷ 1.4 mm
Compensated Temperature: -10 ÷ +40°C
Temperature range: -35 ÷ +65°C
Temperature effect on zero balance: ±0.018 % RO/10°C
Temperature effect on output: ±0.014 % output/10°C
Rated output RO: 3.0 ± 0.003 mV/V
Zero balance: ±1 % RO
Insulation resistance: > 5000 MOhm
Input resistance: 350 ±3.5 Ohm
Output resistance: 350 ±3.5 Ohm
Recommended input: 5 ÷ 12 Vdc/ca

Certifications

  • EAC
  • OIML
  • NTEP