The tension load cell 60001 has been designed for the industrial weighing of small tanks and hoppers. The S-type load cell 60001 has excellent linearity and accuracy features and excellent overload resistance of over 300%. Made of nickel-plated steel, the traction load cell 60001 has a watertight protection for use in severe environmental conditions. PWS: 29/2014
Technical Specifications in PDF
Rated load (RL): 50, 100, 250, 500, 1000, 2500, 5000, 10000 Kg |
Combined error: < ±0.02 % RL |
Repeatability: < ±0.01 % RL |
Creep (30 minutes): ±0.017 % RL |
Safe overload: 150 % RL |
Ultimate overload: 300 % RL |
Material: Nickel steel |
Degree of protection: IP67 |
Accuracy class: 3000 OIML (250 ÷ 2500 kg) |
Deflection: 0.3 ÷ 0.6 mm |
Compensated Temperature: -10 ÷ +40°C |
Temperature range: -18 ÷ +65°C |
Temperature effect on zero balance: < ±0.0010 % RO/°F |
Temperature effect on output: < ±0.0007 % output/°F |
Rated output RO: 3 mV/V ±0.25 % |
Zero balance: ±1 % RO |
Insulation resistance: > 1000 MOhm |
Input resistance: 343 ÷ 450 Ohm |
Output resistance: 349 ÷ 355 Ohm |
Recommended input: 5 ÷ 15 Vdc/ac |