The PS014 off-center load cell (with degree of protection IP66) ensures high accuracy even with off-center loads and is normally used with filling scales and direct platforms up to 200 x 200 mm. PWS: 01/2016
Technical Specifications in PDF
Rated load (RL): 0.3, 0.6, 1.2, 3 kg |
Combined error: < ±0.017 % RO |
Repeatability: < ±0.01 % RO |
Creep (30 minutes): < ±0.016 % RO |
Accuracy class: 3000 OIML |
Deflection: 0.3 - 0.5 mm |
Compensated Temperature: -10 ÷ +40°C |
Temperature range: -20 ÷ +70°C |
Temperature effect on zero balance: < ±0.01 % RO/5°K |
Temperature effect on output: < ±0.006 % RO/5°K |
Rated output RO: 0.9 ±0.2 mV/V |
Insulation resistance: > 5000 MOhm |
Input impedance: 400 ±20 Ohm |
Maximum input voltage: 15 V |
Nominal input voltage: 10 V |
Output impedance: 350 ±3 Ohm |
Degree of protection: IP66 |