The TRZ HT load cell, built in stainless steel, has been designed for the industrial weighing of small tanks and hoppers and it is ideal for working in harsh environments and at high temperatures. It has excellent characteristics of linearity and precision and it owns watertight protection for use in severe environmental conditions and overload resistance over 300%. PWS: 29/2014
Technical Specifications in PDF
Rated load (RL): 100, 250, 500, 750, 1000, 2500, 5000, 7500, 10000 Kg |
Combined error: ±0.05 % RO |
Repeatability: ±0.02 % RO |
Creep (20 minutes): ±0.03 % RO |
Safe overload: 150 % RL |
Ultimate overload: > 300 % RL |
Material: Stainless steel AISI 17-4PH |
Degree of protection: IP67 |
Deflection: 0.3 mm |
Compensated Temperature: -10 ÷ +50°C |
Temperature range: -20 ÷ +150°C |
Temperature effect on zero balance: ±0.005 % RO/°C |
Temperature effect on output: ±0.005 % on output/°C |
Rated output RO: 2.0 mV/V ±0.1 % |
Insulation resistance: > 5000 MOhm |
Input resistance: 350 ±20 Ohm |
Output resistance: 350 ±5 Ohm |
Recommended input: 2 ÷ 15 Vdc/ac |