The CVS HT cell, made of steel, has been designed for the measurement of forces and works both in tension and compression. It has excellent linearity and accuracy and withstands overloads of over 300%. It has a watertight seal for use in severe environmental conditions, especially where there are high temperatures. PWS: 14/2017
Technical Specifications in PDF
Rated load RL: 5, 10, 20, 30, 50, 100, 200, 300, 600, 1000 kN |
Combined error: ±0.08 % RO |
Repeatability: ±0.02 % RO |
Creep (20 minutes): ±0,02 % RO |
Safe overload: 150 % RL |
Ultimate overload: > 300 % RL |
Material: Stainless steel 17-4PH |
Degree of protection: IP67 |
Deflection: 0.35 mm |
Compensated Temperature: -10 ÷ +90 °C |
Temperature range: -20 ÷ +120 °C |
Temperature effect on zero balance: < ±0.005 % RO/°C |
Temperature effect on output: < ±0.005 % RO/°C |
Rated output RO: 2.0 mV/V ±0.1 % |
Zero balance: < ±1.5 % RO |
Insulation resistance: > 5000 MOhm |
Input resistance: 700 ±20 Ohm |
Output resistance: 700 ±5 Ohm |
Recommended input: 2 ÷ 15 Vdc/ac |