Double shear load cell. Accuracy class ± 0.05%. Service temperature up to 150 °C. Measuring element from Alloy Steel with nickel plated treatment. Input cable connection through hermetic connector. Protected IP 67 (EN 60529). Applications: Ladle turret and ladle ferry scales, scrap bucket, roller table, tundish cars, hopper and silos in high temperature environments for the Metal Industry. Ideal to use with MC-315 or DAT S 400 or DAT 1400 without forgetting CGS 4 and the Tester 1008. PWS: 09/2021
Technical Specifications in PDF
Rated Load (RL): 40, 50, 100, 150, 200 t |
Combined error: < ± 0.05 % RO |
Repeatability: < ± 0.04 % RO |
Creep (30 minutes): < ± 0.05 % RO |
Safe overload: 150 % RL |
Ultimate overload: >= 180 % RL |
Degree of protection: IP 67 |
Accuracy class: ± 0.05 % |
Deflection: 0.6 ÷ 1 mm |
Compensated Temperature: -10 ÷ +100 °C |
Temperature range: -30 ÷ +150 °C |
Temperature effect on zero balance: < ± 0.025 % RO / 5 °C |
Temperature effect on output: < ± 0.015 % RO / 5 °C |
Rated output RO: 2 ± 0.25 % mV/V |
Zero balance: < ± 2 % RO |
Insulation resistance: > 5.000 M Ohm |
Input resistance: 800 ± 30 Ohm |
Output resistance: 700 ± 5 Ohm |
Recommended input: 5 ÷ 15 Vdc/Vac |