The BLH NOBEL KOSD load cell is easy and immediate to install and its cylindrical shape facilitates replacement in case of need. The KOSD load cell is suitable for force measurement applications and it is ideal for cranes and offshore installations. PWS: 45/2012
Technical Specifications in PDF
Rated load RL: 1000, 2000 kN |
Combined error: ±1 % RO |
Repeatability: 0.5 % RO |
Safe overload: 100 % RL |
Ultimate overload: 200 % RL |
Safe sideload: 100 % RL |
Ultimate sideload: 200 % RL |
Material: Stainless steel |
Degree of protection: IP67 |
Temperature range: -30 ÷ +70 °C |
Temperature effect on zero balance: ±0.04 % RO/°C |
Temperature effect on output: ±0.04% of output/°C |
Rated output RO: ± 2 mV/V |
Zero balance: ±5% of R.O. |
Insulation resistance: >4 G Ohm |
Input resistance: 700 ± 5 Ohm |
Output resistance: 700 ±5 Ohm |
Recommended input: 10 Vdc/ac |
Maximum supply voltage: 18 Vdc/ac |
Hardness: 350 ÷ 20 HB |