BLH Nobel load cell KOM-1

KOM-1

The BLH NOBEL KOM-1 load cell, designed to be robust, is suitable for loading and controlling level in storage tanks. The KOM-1 load cell is quick and easy to install and it is used for weighing systems and first level monitoring. The load cell BLH NOBEL KOM-1 is also available for extreme temperature from - 40 to + 100 °C. PWS: 37/2014

Further Information

Technical Specifications in PDF

Product code: -_-

Download  

Technical Specifications

Rated load RL: 10, 20, 50, 100, 200 kN
Combined error: 0.25 % RO
Repeatability: 0.25 % RO
Safe overload: 100 % RL
Ultimate overload: 200 % RL
Material: Stainless steel
Degree of protection: IP67
Temperature range: -40 ÷ +80 (+100 optional)°C
Temperature effect on zero balance: ±0.04 % RO/°C
Temperature effect on output: ±0.04 % output/°C
Rated output RO: 1 mV/V
Zero balance: ±5 % RO
Insulation resistance: > 4 G Ohm
Input resistance: 350 ±5 Ohm
Output resistance: 350 ±5 Ohm
Recommended input: 10 Vdc/ac
Maximum supply voltage: 18 Vdc/ac
Tolerance of shunt calibration values: ±1 %
Material (accessories): Yellow chromate steel

Certifications

  • EAC
  • ATEX
  • IECEx