BLH Nobel load cell KIMD-M

KIMD-M

The BLH NOBEL KIMD-M load cell has an high accuracy, it is easy to install and it has a movable loading point. The BHL NOBEL KIMD-M load cell is able to handle the expansion due to increases of temperature and it has a high load capacity. It is ideal for weighing tanks, silos, vessels and big silos. The load cell BLH NOBEL KIMD-M is also available for extreme temperatures from - 40 to + 100 °C. PWS: 37/2014

Further Information

Technical Specifications in PDF

Product code: -_-

Download  

Technical Specifications

Rated load RL: 500, 1000, 1500, 2000 kN
Combined error: ±0.1 % RO
Repeatability: 0.02 % RO
Creep (30 minutes): ±0.03 % RL
Safe overload: 100 % RL
Ultimate overload: 200 % RL
Material: Yellow chromate steel
Degree of protection: IP67
Temperature range: -40 ÷ +80 (+100 optional)°C
Temperature effect on zero balance: ±0.005 % RO/°C
Temperature effect on output: ±0.005 % of output/°C
Rated output RO: 1.0 mV/V ±0.25 %
Insulation resistance: > 4 G Ohm
Input resistance: 350 ± 5 Ohm
Output resistance: 350 ±0.5 Ohm
Recommended input: 10 Vdc/ac
Maximum supply voltage: 18 Vdc/ac
Tolerance of shunt calibration values: ±0.25 %

Certifications

  • EAC
  • ATEX
  • IECEx

Related products