The BLH NOBEL KIMD-M load cell has an high accuracy, it is easy to install and it has a movable loading point. The BHL NOBEL KIMD-M load cell is able to handle the expansion due to increases of temperature and it has a high load capacity. It is ideal for weighing tanks, silos, vessels and big silos. The load cell BLH NOBEL KIMD-M is also available for extreme temperatures from - 40 to + 100 °C. PWS: 37/2014
Technical Specifications in PDF
Rated load RL: 500, 1000, 1500, 2000 kN |
Combined error: ±0.1 % RO |
Repeatability: 0.02 % RO |
Creep (30 minutes): ±0.03 % RL |
Safe overload: 100 % RL |
Ultimate overload: 200 % RL |
Material: Yellow chromate steel |
Degree of protection: IP67 |
Temperature range: -40 ÷ +80 (+100 optional)°C |
Temperature effect on zero balance: ±0.005 % RO/°C |
Temperature effect on output: ±0.005 % of output/°C |
Rated output RO: 1.0 mV/V ±0.25 % |
Insulation resistance: > 4 G Ohm |
Input resistance: 350 ± 5 Ohm |
Output resistance: 350 ±0.5 Ohm |
Recommended input: 10 Vdc/ac |
Maximum supply voltage: 18 Vdc/ac |
Tolerance of shunt calibration values: ±0.25 % |