The MC 382 product is a weight loss flow regulator used in dynamic weighing that integrates weight and velocity variables and performs the flow regulator function set via PI of the analog output. It is possible to use it as a SLAVE doser, with the set point setting as a percentage on the full scale by means of a serial connection to our instruments and display the status of the I / O, the current weight, the instantaneous speed and the set correction factor. PWS: 20/2012
Technical Specifications in PDF
Measuring range: -3.9 ÷ +3.9 mV/V |
Input sensitivity: 0.02 µV/count |
Full scale non-Linearity: <0.01 % |
Gain drift: <0.001 % full scale/°C |
Display: LCD alphanumeric backlit 16 x 2 scripts |
A/D Converter: 24 bit |
Trasducer input voltage: 5 Vdc / 90 mA ; max 6 (350 Ohm) |
Degree of protection: IP54 |
Visible resolution (in divisions): > 60000 |
Divisions value (adjustable): x1, x2, x5, x10 |
Temperature range: -10 ÷ +50 °C (max 85% humidity without condensation) |
Storage temperature: -20 ÷ +70°C |
Logic output: outputs (NA) MAX 115 Vca /30 Vdc 0.5 A cad. |
Logic input: 8 optoisolated 12 / 24 Vcc PNP |
Serial port: COM1: RS232 half duplex; COM2: RS422/RS485 half duplex |
Power supply: 230 (115) Vca 50-60 Hz ; 15 VA |
Regulatory compliance: EN50081-1, EN50082-2 for EMC EN61010-1 for electrical security |
Analog output: 0 ÷ 10 V, 0 ÷ 5 V, 0 ÷ 20 mA, 16 bit; R (V)>10 K Ohm, (I)<300 Ohm |
Drilling template: 139 x 67 mm (L x H) |
Dimensions: 144 x 72 x 120 mm (L x H x D) |
Fieldbus: Modbus RTU, Profibus DP external mounting on DIN guide |
Baud rate: 9600 RS232 - 38400 RS485 |
Transmission distance: 15m (RS232C), 1000m (RS422; RS485) |